Trench SiC MOSFET Explained: The Specific On-Resistance, Die-Area and Switching-Loss Math Behind onsemi M4 and Nexperia's 750 V Shift

Cross-section comparing a planar SiC MOSFET cell with a denser trench SiC MOSFET cell, with current flowing down the trench sidewalls

Bottom line first: Two SiC suppliers moved to trench gates in the same week. onsemi says its new trench platform cuts specific on-resistance by 20–50%. Nexperia, whose earlier 1200 V parts were planar, launched its first 750 V trench MOSFETs. A lower specific on-resistance means a smaller die for the same RDS(on). A smaller die means more chips per wafer, smaller packages and less switching charge. Here is the math, and the trade-off the press releases mention only briefly.

What happened: two trench SiC MOSFET launches in one week

On November 10, 2026, onsemi introduced EliteSiC M4, its fourth-generation SiC platform and its first built on a trench architecture. Its claims against the previous generation:

  • Specific on-resistance (RSP) down 20%–50%
  • Switching figures of merit improved 67% in hard switching and 50% in soft switching
  • Up to 30% higher power density and 35% lower losses
  • Qualification for 185 °C and above. A 750 V automotive traction bare die is available now, with parts up to 1200 V expected from 2027.

On November 11, Nexperia announced a 750 V trench SiC MOSFET family, including its first TOLL packages, in industrial and AEC-Q101 versions. At electronica, Nexperia's Sebastian Fahlbusch told Power Electronics News that the TOLL parts come in 20, 40 and 60 mΩ classes. He said trench gives "a denser cell" and smaller dies. He also said planar keeps "very stable RDS(on) across temperature," and the two are "complementary." The first targets are 400 V EV onboard chargers and DC-DC converters, then AI power front ends and BESS. Traction inverters come "later."

1. Trench SiC MOSFET basics: why the gate goes into the crystal

In a planar SiC MOSFET, the channel runs along the flat wafer surface. Current then turns down through a narrow neck between two p-wells, called the JFET region, before it reaches the drift layer. Three things limit how small that cell can get. The JFET neck needs width. The surface channel has poor electron mobility on the standard SiC face. Each cell needs a fixed horizontal gate overlap.

A trench device etches the gate down into the crystal. The channel runs vertically along the trench sidewall. That removes the JFET neck and lets the cells sit much closer together. The sidewall crystal plane also usually gives better channel mobility than the planar surface (the size of that gain depends on the process, so treat any exact figure as to verify). More channel width per square millimetre gives a lower specific on-resistance:

RSP = RDS(on) × Aactive   (mΩ·cm²)
RSP ≈ Rchannel + RJFET + Rdrift + Rsubstrate (all area-normalised)

At 750 V, the drift layer is thin, so the channel and JFET terms make up a large share of the total. That is why trench gains are largest at 650–750 V and smaller at 1200 V and above, where drift resistance dominates. It also helps explain why both launches lead with 750 V.

2. Die-area math: what a 20–50% RSP cut buys

Hold the target RDS(on) fixed and solve for area:

A = RSP / RDS(on)

Worked example (illustrative values, not vendor data): suppose an older planar 750 V process reaches RSP = 2.0 mΩ·cm². A 20 mΩ die then needs 2.0 / 20 = 0.10 cm², or 10 mm² of active area. At onsemi's quoted range:

  • RSP −20% → 1.6 mΩ·cm² → 8 mm²
  • RSP −50% → 1.0 mΩ·cm² → 5 mm²

Area translates almost directly into cost. On a 200 mm SiC wafer, gross die count scales roughly with 1/A, minus edge loss. So halving the area can come close to doubling the dies per wafer, and yield improves too, because a smaller die is less likely to land on a killer defect. (We covered the wafer-side cost math in 300 mm SiC Wafer Explained.) A smaller die also has less gate, drain and output charge, and that feeds straight into point 3.

Key point: A trench SiC MOSFET doesn't change what 20 mΩ means at the terminals. It changes how much silicon carbide it takes to get there. At 750 V, cutting specific on-resistance mainly lowers cost and capacitance. It does not have to lower conduction loss.

3. Switching-loss math: why the figure of merit matters more than RDS(on)

Total MOSFET loss in a hard-switched converter is:

Ptotal = Irms² · RDS(on)(Tj) + (Eon + Eoff) · fsw

Worked example (illustrative): an 11 kW onboard-charger leg switching at 100 kHz, with Eon + Eoff = 100 µJ per cycle at the operating point, loses 100 µJ × 100,000 = 10 W per switch just in switching. Switching figures of merit usually multiply resistance by a charge or energy, for example RDS(on) × QGD or RDS(on) × Eoss. If a 67% FOM improvement means the product shrinks by a factor of 1/1.67 at the same RDS(on), the switching energy falls to about 60%, so 10 W becomes about 6 W. onsemi's release doesn't say which FOM it uses or how the 67% is defined, so this reading is to verify.

Designers can take that 4 W saving in two ways:

  • Keep fsw and run cooler, or shrink the heatsink.
  • Raise fsw by about 1.67× at the same loss, which shrinks the magnetics. Inductor size scales roughly with 1/f for a fixed ripple current. That is where "30% higher power density" comes from in practice. For more on how OBC magnetics and DC-link sizing interact, see Single-Stage OBC Explained.

4. The trench trade-off: hot RDS(on), gate-oxide field and 750 V margin

Hot RDS(on). Datasheets quote RDS(on) at 25 °C, but converters run at Tj = 125–150 °C. Conduction loss is I² × R(T). Worked example (illustrative multipliers, check each datasheet): a 40 mΩ part carrying 20 A RMS loses 400 × 0.040 = 16 W cold. With a hot-to-cold ratio of 1.4×, that becomes 22.4 W. At 1.8×, it is 28.8 W. That is the gap Nexperia's engineer pointed to when he said planar has "very stable RDS(on) across temperature" for heavy-load uses like EV chargers. When you compare parts, always use RDS(on) at your real Tj, not the cold headline number.

Gate-oxide field. The trench bottom corner concentrates the electric field in the gate oxide when the device blocks high voltage. Trench designs bury p-type shielding regions under or beside the trench to protect it. That shielding adds design complexity, and it is the main reason planar held on in SiC for so long. Long-term oxide reliability data for each new trench generation is something to ask your supplier for directly.

Why 750 V instead of 650 V. A 400 V-class EV pack can sit around 450–470 V at full charge (typical range, to verify for a given pack). Add a switching overshoot of V = Lloop · di/dt. With 10 nH of loop inductance and 2 A/ns, that is 10 nH × 2×10⁹ A/s = 20 V. Apply a common 80% voltage derating:

650 V × 0.8 = 520 V  → 470 + 20 = 490 V leaves ~30 V of headroom
750 V × 0.8 = 600 V  → the same 490 V leaves ~110 V

This is why Fahlbusch said "750 V gives you more safety margin" for 400 V cars. It is also why low-inductance packages like TOLL matter: halve Lloop and you halve the overshoot. For the bigger picture on why voltage class drives SiC adoption in EVs, our video From 400V to 800V: The Silicon Carbide Revolution walks through it.

To verify:
  • The 2.0 mΩ·cm² baseline, the 100 µJ switching energy and the 1.4×/1.8× hot multipliers are illustrative numbers for the math, not onsemi or Nexperia datasheet values.
  • How onsemi defines its "67% hard-switching FOM" improvement (which FOM, and against which part) is not stated in the release.
  • The full-charge voltage of a "400 V" pack varies by cell chemistry and series count. Check the actual pack.
  • Nexperia's 750 V trench parts are based on its Mitsubishi Electric partnership, per the interview. Per-part temperature coefficients are in the datasheets, not the press release.

What to take away: how to choose between trench and planar SiC

  • Trench SiC MOSFETs win on area: lower RSP means a smaller die, lower charge and higher switching frequency. This matters most at 650–750 V.
  • Planar can still win when hot: for parts that sit at high load and high Tj for hours (chargers, some industrial drives), compare RDS(on) at 150 °C, not 25 °C.
  • 750 V is the new 400 V-pack default: the extra 100 V of blocking voltage covers full-charge voltage, overshoot and derating with room to spare.
  • Watch the 1200 V trench rollout in 2027: that is where trench meets 800 V EVs and the 800 VDC data-center bus.

Sources: onsemi, Nov 10, 2026 · Nexperia, Nov 11, 2026 · Power Electronics News, Nov 20, 2026